Eliminate Exhaust Requirements for Chemicals

Many businesses store chemicals such as chlorine, acids, solvents, and strong cleansers that must be mechanically ventilated all the time. Usually, the entire storeroom is exhausted by a rooftop or wall- mounted fan. This fan must operate 24 hours a day, to include the regular business hours when there is a surcharge peak demand fee.

A little rearrangement of the storage facility may be all that is required to avoid using this exhaust fan all the time. If the chemicals are relocated to a smaller room that can be well ventilated by a smaller fan, the cost of exhausting a large storage room—and its larger-horsepower fan motor—is avoided.

Many chemicals are relatively inert at room temperature. A thermostat- controlled fan in a space containing such compounds further reduces energy usage by operating the fan only when the space temperature is high enough to cause the emission of fumes from the materials.